User Tools

Site Tools


wiki:water_availabilty

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
wiki:water_availabilty [2018/07/11 11:16] sebastianwiki:water_availabilty [2018/07/16 15:36] (current) eurac
Line 1: Line 1:
-==== Surface water for drinking with minor or no treatments - Supply ====+====== Surface water for drinking with minor or no treatments - Supply ======
  
-==== General description====+==== General description ====
  
 The surface water supply is displayed as annual average available water runoff. Using the INVEST water yield model, the annual average quantity of water runoff from each subcatchment of the Alpine space is calculated. The model estimates the water runoff based on gridded information on climatic, soil, topographic and landcover characteristics. The surface water supply is displayed as annual average available water runoff. Using the INVEST water yield model, the annual average quantity of water runoff from each subcatchment of the Alpine space is calculated. The model estimates the water runoff based on gridded information on climatic, soil, topographic and landcover characteristics.
Line 17: Line 17:
   * <font 14px/inherit;;inherit;;inherit>Annual average runoff</font>   * <font 14px/inherit;;inherit;;inherit>Annual average runoff</font>
  
-==== Calculation processes====+==== Calculation processes ====
  
-  - <font 14px/inherit;;inherit;;inherit>**Run INVEST water yield model**</font>+<font 14px/inherit;;inherit;;inherit>**(1) Run INVEST water yield model**</font>
  
 <font 14px/inherit;;inherit;;inherit>**Download and Install INVEST water yield model**</font> <font 14px/inherit;;inherit;;inherit>**Download and Install INVEST water yield model**</font>
Line 66: Line 66:
  
 As most input data, were physically determined values, and hence are not to be changed. The calibration, after assessing the sensitivity was done with the annually average evapotranspiration coefficient. Therefore, comparing the dataset with the observation-based map of mean annual runoff from Beck (2012), step-wise adjustments of the KC- (Evapotranspiration coefficient table)values are made towards minimising the error to reach a threshold of max 10-15 % error rate. This was done in a semi-automatic calibration scheme in python and R environment. As most input data, were physically determined values, and hence are not to be changed. The calibration, after assessing the sensitivity was done with the annually average evapotranspiration coefficient. Therefore, comparing the dataset with the observation-based map of mean annual runoff from Beck (2012), step-wise adjustments of the KC- (Evapotranspiration coefficient table)values are made towards minimising the error to reach a threshold of max 10-15 % error rate. This was done in a semi-automatic calibration scheme in python and R environment.
 +
 +{{:en:20181701drinking_water_supply_new.jpg?direct&2401x1247}}
 +
 +{{:en:test_legens.jpg?nolink&500x297}}
  
  
wiki/water_availabilty.1531300617.txt.gz · Last modified: 2018/07/11 11:16 by sebastian